MODEL 5050LL-PTK : Pressure Transducer
General Description:
HydroLynx pressure transducers are specifically designed to meet the rigorous environments
encountered in level measurement applications. These transducers provide repeatable,
precision depth measurements under the most adverse conditions.
All transducers incorporate isolated diaphragm sensors which are specifically designed
for use with hostile fluids and gases. These sensors utilize a silicon pressure cell
that has been fitted into a stainless steel housing with an integral, compliant stainless
steel barrier diaphragm. This sensor assembly is housed in a rugged 316 SS case which
provides for a variety of pressure inputs as well as electrical output connections.
Model 5050LL-PTK pressure transducers feature high performance and internal signal
conditioning. They are available in both 4 to 20 mA and 0 to 5 Vdc output versions. |
|
|
 |
 |
 |
|
MODEL 5050LL-PTK : FEATURES
- High static accuracy and repeatability
- Welded 316 SS construction
- Small rugged package
- Broad selection of pressure ranges
- 100% computer-tested, calibrated and serialized
- Unique cable seal system
- Fully temperature compensated
|
|
|
 |
 |
|
MODEL 5050LL-PTK : SPECIFICATIONS
- Performance
- Pressure range: 0 - 5 through 0 - 300 PSIG
- Static accuracy*:
- ± 0.10% FSO BFSL (specify)
- ± 0.25% FSO BFSL (specify)
- ± 0.50% FSO BFSL (specify)
- ± 1.0% FSO BFSL (specify)
- Thermal Error**: 0.05% FSO/°C worst case
- Proof Pressure: 1.5 x rated pressure
- Burst Pressure: 2.0 x rated pressure
- Resolution: Infinite
*Static accuracy includes the combined errors due to nonlinearity, hysteresis and
nonrepeatability on a Best Fit Straight Line basis, at 25°C per ISA S51.1.
**Thermal error is the maximum allowable deviation from the Best Fit Straight Line
due to a change in temperature, per ISA S51.1
- Environmental
- Comp. temp. range***: 0 to 50 °C
- Operating temp. range: -10 to 60 °C
*** Tighter tolerances on thermal error and/or a wider compensated temperature range
are available on request. Consult the sales office.
- Electrical
- Excitation: 9 to 30 Vdc
- Input current: 20 mA maximum
- Output: 0-5 Vdc (3 wire) or 4-20 mA (2 wire)
- Zero offset, max:
- 0-5 Vdc: 60 mV
- 4-20 mA: 0.12 mA
- Output impedance: <10 ohms
- Insulation resistance: 100 W at 50 Vdc
- Circuit protection: Polarity, surge & shorted output
- Physical
- Dimensions: 1 in. dia. x 4.02 in. long
- Weight: 7 oz (not incl. cable)
- Cable: Polyurethane jacketed shielded cable with polyethylene vent tube
- and Kevlar tension members - 200 lbs. pull strength. Tefzel jacket optional.
- Wetted materials: 316 SS, Fluorocarbon
- Mounting provisions: Suspended by cable.
For turbulent conditions, specify optional mounting bracket.
|
|
|
 |
|
 |
|
|
|
|
|
5050LL-PTK
Pressure Transducer
0 to 5 Vdc
Specify PSI Range for Measured Range Min / Max
- 0-1 PSI 1.7 ft./3.4 ft.
- 0-5 PSI 8.5 ft./17 ft.
- 0-15 PSI 17 ft./34 ft.
- 0-30 PSI 34 ft./68 ft.
5050LL-PTK-420
Pressure Transducer
4 to 20 mA
5050LL-PTK-C
Additional Cable, per foot
5050LL-PTK-M
Mounting Bracket for Standpipe Installation
5050LL-PTK-F
¼ in. NPT Pressure Fitting |
|
|
 |
 |
|
|
|
|
|